Baymak Boiler Water Pressure Refill: Step-by-Step Guide

Estimated time: ~4 min5 stepsVerified:

Independent guide — no official affiliation with com.tr.

Time~4 min Steps5 DifficultyEasy Official sourcebaymak.com.tr Last updated24 September 2026
Share

Short answer

When a Baymak boiler's pressure drops below 1 bar the display may show a lockout and the device can stop. Refill with the filling loop under the boiler to 1.2–1.8 bar: open the loop slowly, watch the display, close it firmly at the target value and reset if needed. Constant drops point to a leak or expansion vessel fault.

Official page

baymak.com.tr

Official Baymak website

01 — Step-by-step fix

Step-by-step fix

  1. ADIM 01

    Run the safety checks

    Make sure the area under the boiler is dry; if you see standing water, find the leak first. Check that radiator valves are open.

  2. ADIM 02

    Locate the filling loop

    On Baymak models the filling loop is a grey/black plastic or brass tap under the boiler; on some models you turn a lever to 'open'. Your manual's diagram shows which valve is the loop.

    Don't confuse the loop with the gas valve: the gas valve has a yellow lever and pipes toward the gas line. If unsure, check the manual before turning anything.

  3. ADIM 03

    Slowly raise pressure to 1.2–1.8 bar

    Open the loop slowly while watching the display. Close it around 1.5 bar. Never exceed 2.5 bar; overpressure vents water through the safety valve.

  4. ADIM 04

    Close the loop firmly and reset

    Turn the loop fully closed. If the display shows a lockout, press reset or power-cycle the breaker for 30 seconds.

  5. ADIM 05

    Watch the pressure over the next days

    After a correct refill the pressure should stay stable for weeks. If it drops in 2–3 days, bleed radiators again and retry. Continued drops mean a leak in the system.

02 — Frequently asked questions

Frequently asked questions

What is the ideal pressure on a Baymak boiler?

1.2–1.8 bar cold. Rising to 2–2.2 bar while running is normal; near 3 bar suggests an expansion vessel issue.

I filled it but the pressure still reads low

Confirm the loop is fully closed and you turned the right valve. The display may lag — read again after a reset. If it's still low or keeps dropping, there's a leak.

The pressure is too high — what now?

Drain a little water from any radiator bleed valve to bring it to 1.5–1.8 bar. If it climbs to 3 bar repeatedly and the safety valve opens, have the expansion vessel checked.

Did this guide solve it?