Boiler Pressure Too Low: How to Refill to 1.5 Bar

Estimated time: ~5 min5 stepsVerified:

Independent guide — no official affiliation with the platforms mentioned.

Time~5 min Steps5 DifficultyEasy Last updated2 September 2026
Share

Short answer

When boiler pressure drops below 1.0 bar, slowly open the filling loop underneath until the gauge reads 1.5 bar, then close it. It takes 2–3 minutes. Frequent drops indicate a leak or faulty expansion vessel — call a technician.

01 — Step-by-step fix

Step-by-step fix

  1. ADIM 01

    Let the boiler cool down

    Refilling a hot system gives false readings due to expansion. Switch off and wait 15–20 minutes.

  2. ADIM 02

    Find the filling loop

    It's a small tap or flexible connector under the boiler, labelled 'filling loop' in the manual.

  3. ADIM 03

    Raise pressure to 1.5 bar

    Open the valve slowly and watch the gauge. Close it fully at 1.5 bar.

  4. ADIM 04

    Bleed radiators if needed

    Open radiator bleed valves until water appears, then re-check the pressure.

  5. ADIM 05

    Log frequent drops

    If pressure drops more than once a week, suspect a leak or expansion-vessel membrane — call service.

02 — Frequently asked questions

Frequently asked questions

What should boiler pressure be?

1.0–1.5 bar when cold is ideal. Rising to 2.0 bar during heating is normal; 3 bar is the safety limit.

Pressure keeps dropping — what should I do?

Check visible leaks first (valves, filling loop). If none, the expansion vessel membrane may be faulty — needs a technician.

How do I lower excessive pressure?

Bleed a radiator slightly to release water until it returns to 1.5 bar. Don't use the boiler's drain valve.